Non FBC (CT Model) |
|
|
| Range |
: |
2 TPH to 8TPH |
|
|
|
Pressure
|
: |
150 PSI to 450 PSI |
|
|
|
| Type |
: |
Water cum Smoke Tube Boiler; Membrane Water Wall
Panel Lined Radiant Furnace with Shell & Tube Boiler |
|
|
|
| Options |
: |
- Pneumatic Auto Firing
- Dumping Grate for Bagasse firing
- Traveling Grate for Higher Capacities
- Additional OIL / GAS Firing
- Steam Super Heating
- Provision for FBC Conversion
|
|
|
|
| Salient Features |
: |
- Ideal for FUELS with higher VOLATILE CONTENT & Lighter Fuel e.g. Lignite, Rice Husk, Bagasse, Ground Nut Shell etc.
- Very High THERMAL EFFICIENCY due to Efficient Combustion & Minimal Radiation Losses .
- Higher Free Board Space & Large Combustion Volume.
- Minimum Choking hence Lower Cleaning Frequency
- Large Water Holding & Steam Space
- Better response to fluctuating Steam Load
- Quicker Initial Steaming
- Superior MEMBRANE TECHNOLOGY in Packaged & Large Boilers
- Minimum usage of Refractory in Furnace hence Lower Maintenance & Minimum Air Leakages.
- Easy in : * Operation * Maintenance * Cleaning
|
|
FBC (CTF Model) |
|
| |
Range
|
: |
3 TPH to 16 TPH (Husk / GN Shell / Saw Dust)
5 TPH to 16 TPH (Coal/Lignite) |
|
|
|
Pressure
|
: |
150 PSI to 450 PSI |
|
|
|
| Type |
: |
Water cum Smoke Tube Boiler; Membrane Water Wall Panel
Lined Radiant - FBC Furnace with Shell & Tube Boiler |
|
|
|
Options
|
: |
- Dual Furnace: Manual Firing cum FBC firing (CTD model) for special applications
- Over - bed AND / OR Under - bed Fuel Feeding
- Fuel Feeding Arrangement:
* Vibratory Feeder / Screw Feeder / Rotary Feeder
* Eddy Current Coupling / AC Drive / DC Drive
- Steam Superheating
- FBC without in-bed Tube / Coil for special applications
- Multi Cyclone Dust Collector / Bag Filter
- Air Pre - heater AND / OR Water Pre - heater
|
|
|
|
| Salient Features |
: |
- Very High THERMAL EFFICIENCY due to :
* Low Combustion Air to Fuel Ratio
* Higher Combustion Volume & Free Board resulting in Efficient Combustion
* Minimal Radiation Losses due to Membrane Water Wall Panelled Radiant Furnace
* Minimal Air Leakage in Furnace due to Membrane Panel
* Higher Effective Heat Transfer Areas
- Automatic Operation for consistent & uninterrupted steaming
- Large Water Holding & Steam Space
- Better response to fluctuating Steam Load
- Superior MEMBRANE TECHNOLOGY in Fluidised Bed Combustion
- Minimum usage of Refractory in Furnace hence Lower Maintenance & Minimum Leakages
|
|
|
|
Instrumentation & Controls for
|
: |
* SAFE Operation
* EASY Operation
* OPTIMAL PERFORMANCE |
|
 |
Range
|
: |
1 TPH to 3 TPH |
|
|
|
Pressure
|
: |
150 PSI to 300 PSI |
|
 |
| Double / Twin Furnace |
|
Range
|
: |
3 TPH to 6 TPH |
|
|
|
Pressure
|
: |
150 PSI to 300 PSI |
|
|
| Type |
: |
Shell & Tube Type, Fully Wet Back, Three Pass, Agro -Waste Fired, Vertical Over feed, Smoke Tube Boilers |
|
|
|
| Fuel |
: |
Husk, Ground Nut Shell, Wooden Chips & other Pulverised Fuels |
|
|
|
| Options |
: |
- Vibratory Feeder OR Screw Feeder
- Variable Speed Drive either by Eddy Current Coupling / DC Drive / AC Drive
- Manual Firing of Wood, Coal, Lignite
- Grate Bars / Nozzles
- Over-feed / Front Door Firing
- Water Pre -heater
- Multi Cyclone Dust Collector with Rotary Air Valve
|
|
|
|
| Salient Feature |
: |
- Automatic (Pneumatic) Operation
- Convenient Operation & Maintenance
- Large Water & Steam Holding Capacity
- Higher Heat Transfer Areas
|
|
 |
| Single Furnace |
|
Range
|
: |
1 TPH to 3 TPH
|
|
|
|
Pressure
|
: |
150 PSI to 300 PSI |
|
 |
| Double / Twin Furnace |
|
Range
|
: |
4 TPH to 6 TPH |
|
|
|
| Pressure |
: |
150 PSI to 300 PSI |
|
|
|
|
|
|
| Type |
: |
Shell & Tube Type, Three Pass, Smoke Tube Internal Furnace Boilers |
|
|
|
| Fuel |
: |
Coal, Lignite, Wood, Briquetted Agro - waste etc. |
|
|
|
Options
|
: |
- Three Furnaces for Higher Capacities (5 TPH to 8 TPH)
- Semi Wet Back / Fully Wet Back
- Vertical Pneumatic Over Feeding for Pulverised Fuel
- Water Pre - heating
|
|
|
|
| Salient Features |
: |
- Minimum Space Requirement .
- Easy & Quick in Erection & Commissioning .
- Easy in Operation & Maintenance .
- Less Susceptible to Poor Water Quality
- Lower Power Consumption
- Best for Coal / Wood Firing.
|
|
|
 |
Range
|
: |
1 TPH to 12 TPH |
|
|
|
Pressure
|
: |
150 PSI to 300 PSI |
|
|
| Type |
: |
Straight, Three Pass, Fully Wet Back, Shell & Tube, Smoke Tube, Oil cum Gas Fired Packaged Boiler. |
|
|
|
| Fuel |
: |
FO, LDO, LSHS, Gas (Natural / Bio) |
|
|
|
Salient Features
|
: |
- Rugged & Durable Design
- Straight Three Pass (No Reverse Flame);
Plain Stiffened, Furnace -Plain & Thicker hence Safer
- Compatible with most imported Oil/Gas Burners
- Suitable for Oil as well as Gas Firing
- Higher Radiation Heat Transfer Area
- Large Combustion Volume hence enhanced Safety & Higher Efficiency
- Atmospheric / Pressurised Water Pre - heating for Higher Capacities
- Easy & Quick in Erection & Commissioning
|
|
TOP |
Range
|
: |
0.5 TPH to 5 TPH |
|
|
|
Pressure
|
: |
150 PSI to 350 PSI |
|
 |
| Type |
: |
Single / Two Pass, Shell & Tube Type, Smoke Tube Boilers with Refractory Lined External Furnace |
|
|
|
| Fuel |
: |
Rice Husk, Ground Nut Shell, Bagasse, Wood, Coal & Other Agro - Waste Fuels. |
|
|
|
Salient Features
|
: |
- Cost Effective & Durable
- Multiple Fuel Firing Option
- Simpler Design & Easy Maintenance
- Less Susceptible to Poor Water Quality
- Lower Power Consumption
- Higher Grate Area & Combustion Volume for Efficient
- Combustion of Agro - Waste Fuel.
|
|
TOP |
Range
|
: |
500 kgs/hr to 2000 kgs/hr |
|
|
|
Pressure
|
: |
150 PSI to 250 PSI |
|
 |
TOP |
| Range |
2 lacs Kcal / hr to 25 lacs Kcal/hr |
|
|
| Type |
: |
Vertical 3 / 4 Pass Heater with Radiant Furnace |
|
|
|
| Fuel |
: |
Coal, Lignite, Bagasse, Wood, Husk, Saw Dust & other Agro - Waste Fuels. |
|
|
|
Salient Features
|
: |
- Radiant Furnace for Higher Efficiency
- Separate Radiation & Convective Coils
- High quality inputs
- Pneumatic firing of fuel like husk, bagasse etc.
- Fluidised Combustion for Special Applications
- Multiple Fuel Firing Arrangement
|
|
TOP |
Range
|
: |
4 TPH to 20 TPH |
|
|
|
| Pressure |
: |
Upto 700 PSI |
|
|
| Type |
: |
Bi-drum Water Tube Boiler with various Furnace options like FBC, Dump Grate, Travelling Grate, Fixed Grate etc. |
|
|
|
| Fuel |
: |
Coal, Lignite, Bagasse, Husk, Wood, Saw Dust
|
|
|
|
| Options |
: |
- Pneumatic firing with fixed / dump grate / Travelling Grate
- FBC -under -bed and / or over -bed Firing
- Steam Super Heating
- Soot Blowing
- Steam Driven Turbo Pump for Power Boilers
|
|
|
|
Salient Features
|
: |
- Ideal for Higher Pressure (upto 700 PSI) and continuous round the year operation like Power Plants, Continuous Process Industries etc.
|
| |
|
|
TOP |
| |
|
|
|
|
Type |
|
Vertical Smoke / Cross Tube Type |
| |
|
|
| Silent Features |
|
- Minimum Space Required.
- Easy & Quick in Erection & Commissioning.
- Convinient Operating & Maintenence
- Best for Coal / Wood firing.
|
| |
|
|
| Options |
|
- Vertical Smoke Tube Type
- Vertical Cross Tube Type
|
| |
|
|
TOP |
|
| Range |
|
50000 Kcal./hr to 10,00,000 Kcal./hr |
| Fuel |
|
Oil / Coal / Wood |
| Type |
|
Horizontal /Smoke Tube Type |
| |
|
|
| Silent Features |
|
- Automated Operation
- Convenient in Operating & Maintenence
- Easy & Quick in Erection & Commissioning.
- Best for Oil / Coal / Wood firing.
|
| |
|
|
| Options |
|
- Horizontal Smoke Tube Type
- Vertical Coil Type.
|
| |
|
|
TOP |

|
|
|
50 Kg/hr. to 600 Kg/hr. |
| |
|
|
|
|
Oil / Electrical |
| |
|
|
| Silant Features |
|
- Instant steam within 4-5 minutes.
- High Quality Steam
- High Efficiency.
- Compact Design.
- Fully Auto Disign.
- Convinient Operating & Maintenence.
- Minimum Space Required.
- Easy & Quick in Erection & Commissioning.
- Cost Effective & Durable.
- Lower Power Consumption
|
| |
|
|
|